Technical
Sound Provided By:
Audio East Inc
70 Wilbur St.
Lowell MA 01851
(978) 937-3944
Please read through the LSMS' typical concert system (below) and see that it meets your artist's criteria, Please forward your Technical rider including your stage plot and input list to Dan Bouchard (
dan@audioeast.com) along with any items that are not met by the system below.
A typical day at Lowell Summer Music Series
12:00PM - Sound Load In - 4 Hands
1:00PM - Band Load In - 6 Hands
4:00PM - Sound Check (open)
5:00PM - Hospitality
5:30PM - Audience Sweep & Gates (LSMS will provide all pre show music)
7:30PM* - Show (either support or first set of headliner)
8:10PM - Intermission
8:30PM* - Headliner
11:00PM - Curfew
*Set lengths may differ for headliners doing two sets so long as there is a 20-minute intermission between sets.
A-System-XLc
Main System
8 - Electro Voice XLc-127DVX Line Array Enclosures (Flown)
6 - Dual 18” 1600w Subs
35k Watts of Tour Class Power / 2 Electro Voice DX38 System Contollers
Klark Teknik Graphic EQ / CD / IPod Doc / 200' 12Channel Drive Line
FOH
48 Channel Midas Verona Console
16 Channel of Dynamics / SPX1000 / SPX2000 / TC – DTWO / TC - MONE
Full Mic / Stand / Cable Package / 40x12 200' Split Snake System
Monitors
8 - Electro Voice Xarray XW15a Wedges / 1 - 1500w 18" Drum Sub
2 - 4 Channel Amp Racks (bi amp) w/ Crest Pro200 Series / Ashley Protea Management
40 Channel Midas Sienna Monitor Console
8 - Ashley GQX3102 Graph / 1 Lexicon MPX550 FX / 4 Channels DBX comp/gate
(More wedges/mixes and sidefills available upon request)
B-System-QRX
(For Indoor Shows & Shows Selling Less than 1000 Seats)
Main System
6 - Electro Voice QRX-153 3 Way Concert Enclosures
4 - Dual 18” 1600w Subs
20k Watts of Tour Class Power
32 Channel Allen and Heath GL2400 Console
Full Mic / Stand / Cable Package / 32x8 200' Split Snake System
Monitors
6 - Electro Voice ZX3 Wedges
1 - 6 Channel Amp Racks
6 - DBX 31 Band Graph
(More available upon request)
32 Channel Allen and Heath GL2800 Monitor Console
Lighting
30 PAR 64 on DMX controller, warm wash and FOH special tower spots
*Power is available for additional lighting*
Power
100 amp/3 Phase CAM Lock Power for sound system/stage power
200 amp/3 Phase dedicated to lighting
100 amp/Single Phase for supplemental onstage power
Staging
Staging is available only on request in 4'x8' sections
FOH Mix Position
85ft from down stage center, center of house
Note: Note: 250ft snake is required to make the run from stage right to FOH mix
Stage Dimensions
30W x 30D x 16"H
Wings 52W x 25D
Main Seating Area
146W x 110D
Seating is a terraced stadium style lawn.
Seating Capacity
1,700
Dressing Rooms
60ft of stage right on 3rd floor accessed via elevator.
Showers
Showers are not available on BHP premises, hotel accommodate for this amenity.
Shore Power
There is NO shore power provided at BHP